VPG飞机称重设备/JetWeigh5? JackPoint |
System Features: |
Capacity range of 15,000 to 600,000 pounds |
Accuracy of ±0.1% of applied load, or ±0.02% of channel capacity, whichever is greater |
G-factor compensation between calibration and operation locations enables accurate and simple operation |
Hermetically sealed, compact stainless steel load cells |
User-friendly, color graphic display with touch screen |
Robust and reliable operation |
Applications: |
Routine weight and center-of-gravity monitoring |
Weight checks after airframe repairs and modifications |
Design proving weight and center-of-gravity determinations |
Software Features: |
Synchronized sampling of all weight channels minimizing the effect of vibration, oscillations and wind |
On-board automatic center of gravity calculation |
Re-configurable load cell arrangement |
3 weight modes meet different environmental conditions |
Automatic latitude and altitude adjustment of weight value |
Automatic zero tracking |
On-board library of up to 200 aircraft types and characteristics |
Diagnostic algorithms check for system errors |
Aircraft weights stored in history file for future comparison and data validation |
SYSTEM COMPONENTS CENTER-OF-GRAVITY ACCESSORY KIT |
? 3 to 5 load cells ? Level and level bar |
? Rugged weighing user terminal ? Plumb bob assembly (2) |
? On-board thermal printer ? Chalk and line |
? Power supply and power cord ? Hydrometers (2) |
? Center-of-gravity accessory kit ? Fuel dipper |
? Jack adapters, cables ? Hydrometer jar and stand |
? Rugged fiberglass carrying case ? Leveling bar |
? 50-ft Steel tape |
? Screwdriver |
? 12-in Steel ruler |
Revere Aircraft Weighing System |
SPECIFICATIONS |
PARAMETER DESCRIPTION SYSTEM |
SYSTEM |
Accuracy 0.1% of applied load or 0.02% of channel capacity, whichever is greater |
Calibration method Dead weight calibration of load cells in factory |
Power 110–240 VAC with 1,2 A Environmental protection Load cells—IP65; |
kit case—high-impact fiberglass carrying case |
Environmental conditions Operating temperature +14°F to +120°F (–10°C to +50°C) |
Storage temperature –4°F to +140°F (–20°C to +60°C) |
Humidity 95% RH, non-condensing |
KIT CONFIGURATON |
PARAMETER MODEL |
JW-15J5 JW-20J5 JW-30J5 JW-40J5 JW-75J5 |
No. of load cells 3 4 3 4 3 |
Cell capacity (lb) 5,000 10,000 25,000 |
Kit capacity (lb) 15,000 20,000 30,000 40,000 75,000 |
Part number 64001-00J5 64001-01J5 64001-02J5 64001-03J5 64001-04J5 |
Resolution (lb) 0.5 0.5 1 1 2 |
Kit weight (lb) 72 78 72 78 72 |
Kit dimensions (in) 32.88” L X 17.5” W X 8.75” H |
JW-100J5 JW-150J5 JW-200J5 JW-300J5 JW-400J5 |
No. of load cells 4 3 4 3 4 |
Cell capacity (lb) 25,000 50,000 100,000 |
Kit capacity (lb) 100,000 150,000 200,000 300,000 400,000 |
Part number 64001-05J5 64001-06J5 64001-07J5 64001-08J5 64001-09J5 |
Resolution (lb) 2 5 5 10 10 |
Kit weight (lb) 78 72 78 96 110 |
Kit dimensions (in) 32.88” L X 17.5” W X 8.75” H |
JW-250J5 JW-425J5 JW-450J5 JW-500J5 JW-600J5 |
No. of load cells 5 5 5 5 3 |
Cell capacity, mains (lb) 50,000 100,000 200,000 |
Cell capacity, nose (lb) 50,000 25,000 50,000 100,000 200,000 |
Kit capacity (lb) 250,000 425,000 450,000 500,000 600,000 |
Part number 64001-16J5 64001-12J5 64001-13J5 64001-14J5 64001-15J5 |
Resolution, mains (lb) 5 10 10 10 20 |
Resolution, nose (lb) 5 2 5 10 20 |
SOFTWARE |
Load Cell Sampling Synchronized sampling of all load cells |
Conversion rate 300 conversions/second per load cell |
Internal resolution 16,777,216 (24 bits) |
Data (displayed and printed) Gross weight; individual load cell weights (kg, lb and %); |
CG location (inches, cm, %MAC). |
System is calibrated in lb or kg. |
Weighing save options Internal memory; serial interface to download (or synchronize) to a PC |